Certification Program Name:Accelerated Convergence Spanning Tree 802.1w
Certification Program ID:10603
Certification Program Category:Switch Interoperability
Description:This verifies a device's ability to converge a layer 2 bridged network using the IEEE 802.1w protocol with multiple vendor combinations
Interpretation:Devices earning this certification have demonstrated the ability to converge and recover failed links using the 802.1w protocol with all possible vendor combinations. 2007 Certified Product Set: 3Com Switch 4200G 3Com Switch 4500G 3Com Switch 5500G-EI Alcatel-Lucent OmniSwitch 6850-P24X Alcatel-Lucent OmniSwitch 9800 Cisco Catalyst 6509-E Enterasys SecureStack™ A2 Enterasys SecureStack™ B3 Enterasys SecureStack™ C3 Enterasys Matrix™ N-DFE Enterasys Matrix™ X Exterme Summit X450a-24t Extreme BlackDiamond 8806 Foundry FastIron Edge X424 Premium Foundry FastIron SX 800 Foundry NetIron MLX-4 Foundry BigIron RX-4 Fujitsu XG700 Fujitsu XG2000 IBM Nortel Layer 2-3 GbE Switch Module IBM Nortel 10Gb Uplink Ethernet Switch Module IBM Nortel 10Gb Ethernet Switch Module HP GbE2c L2/3 Ethernet Blade Switch for HP c-Class BladeSystem 2004 Product Set 3Com: SuperStack 3 Switch 3870 Cisco Systems: Catalyst 6509 Dell: PowerConnect 3324 Dell: PowerConnect 5324 Extreme: BlackDiamond 10808 Foundry: FastIron Edge 9604 Foundry: BigIron MG8 HP: ProCurve 2848 HP: ProCurve 5308 2003 Product Set: 3Com: Switch 4060 3Com: SuperStack Switch 4400 Cisco Systems: Catalyst 6500 Dell PowerConnect 3348 Dell PowerConnect 5224 Enterasys Matrix N3 Foundry FastIron Edge 9604
Product Applicability:This certification is applicable to all LAN switches. It is an optional component of the 2003/2004 Switch Interoperability Study.
Testing Overview:The switches under test will be connected as described below. The Tolly Group will initiate a sequence of PINGs at one-second intervals and validate that both the request and response cross the same path. The Tolly Group will then power off the switch on that path and monitor the number of sequential PINGs lost before the network reconverges and the PINGs achieve success. The Tolly Group will record the reconvergence time in seconds as one more than the number of PINGs lost. (End stations will be configured for the same IP network.)

Note: Certification Program information is intellectual property of The Tolly Group, Inc. and may not be used in any manner without express written permission.

©2006-2007 THE TOLLY GROUP, INC. TERMS OF USE PRIVACY STATEMENT LEGAL CONTACT US